SKU: 12388600503

Human Fc quantification kit - human Fc定量试剂盒

Sale price$135.00 Regular price$150.00
Save 10%

Pay in installments of $37.50 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 19 - Jul 24

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Human Fc quantification kit - human Fc定量试剂盒Product Specification Host Human Stability & Storage 80 Background This kit employs homogeneous time resolved fluorescence technology and can be used to detect Human IgG antibodies in cell culture supernatants. The kit includes an antibody labeled donor Eu (anti Human IgG Eu) and a Human IgG labeled acceptor (Human IgG Ac). The anti Human IgG Eu binds to Human IgG Ac, and when excited by 320 nm light, the donor transfers energy to the acceptor, which

Product Specification


Host Human
Stability & Storage

-80℃

Background

This kit employs homogeneous time-resolved fluorescence technology and can be used to detect Human IgG antibodies in cell culture supernatants. The kit includes an antibody-labeled donor Eu (anti-Human IgG-Eu) and a Human IgG-labeled acceptor (Human IgG-Ac). The anti-Human IgG-Eu binds to Human IgG-Ac, and when excited by 320 nm light, the donor transfers energy to the acceptor, which then emits light at a specific wavelength (665 nm).

Human IgG antibodies in the sample competitively bind to anti-Human IgG-Eu, resulting in a signal inversely proportional to the concentration of Human IgG in the standard. This allows quantification of Human IgG in the sample based on a standard curve. This homogeneous assay requires no washing and enables accurate quantification of total Human IgG.

Components

Component

Concentration

100T

500T

2500T

10000T

Storage Temperature

Anti-Human IgG-Eu*

50×

10μL

50μL

250μL

1000μL

-80℃

Human IgG-Ac*

50×

10μL

50μL

250μL

1000μL

-80℃

IgG Standard

1mg/ml

5μL

10μL

50μL

200μL

-80℃

Assay Buffer

1.5mL

6ml

30mL

120mL

-80℃

Standard Diluent

1.5mL

6ml

30mL

120mL

-80℃


Note: Aliquot immediately after first thaw and store at recommended temperatures. Avoid storage after dilution or repeated freeze-thaw cycles.

Protocol

1. Reagent Preparation

Thaw all reagents at room temperature before use (equilibrate at room temperature for at least 30 min). The reaction volume for the 384-well shallow plate is 20 μL (reagent volumes for the reaction system are shown in Table 2). Calculate the required volume for the experiment before preparation and prepare as needed; the following preparation is for reference only, using 500 assays as an example.

Table 1. Reagent Preparation

Reagent Name

Preparation

Volume per Assay Well (μL)

Anti-Human IgG-Eu

Add 2450 μL Detection Buffer to 50 μL Anti-Human IgG-Eu, mix well, and keep on standby.

5

Human IgG-Ac

Add 2450 μL Detection Buffer to 50 μL Human IgG-Ac, mix well, and keep on standby.

5

IgG Standard

Take 10 μL of the standard stock solution, add 115 μL of standard diluent, mix thoroughly. Standard curve dilutions are as follows.

10


Table 2. Preparation of Standard Working Solutions

Standard Working Solution Concentration

(ng/mL)

Preparation Method

80000.0 10μL standard original stock solution + 115μL standard diluent

20000.0 20μL +60μL standard diluent

5000.0 20μL +60μL standard diluent

1250.0 20μL ③+60μL standard diluent

312.5 20μL ④+60μL standard diluent

78.125 20μL ⑤+60μL standard diluent

19.531 20μL ⑥+60μL standard diluent

4.88 20μL ⑦+60μL standard diluent

1.220 20μL ⑧+60μL standard diluent

0.305 20μL ⑨+60μL standard diluent

Blank

0.0 60μL standard diluent


2. Sample Addition and Controls

Order of sample addition: 10μL standard or sample; 5μL Anti-Human IgG-Eu; 5μL Human IgG-Ac are added sequentially to the 384-well shallow plate. (Note: Human IgG-Ac is added last)

NC: Replace 5μL Human IgG-Ac with 5μL Detection Buffer, and replace sample with 10μL standard diluent.

Maximum Control: Replace sample with 10μL standard diluent.

3.Detection

Seal the plate wells with a plate sealer, centrifuge at 1000 rpm for 1 min, and incubate at room temperature for 1 h. Detect on a TR-FRET compatible microplate reader (excitation wavelength 320 nm, emission wavelengths 620 nm and 665 nm).

[Result Calculation]

1. TR-FRET Ratio Calculation

TR-FRET Ratio = 665nm / 620nm *10000

2. Calculate CV (%)

CV(%)= Standard Deviation/Mean Ratio×100%

[Data Example]

Please note that the following data cannot replace the data obtained in experiments and is provided only as an example. Results may vary depending on the TR-FRET compatible instrument.

Std

Concentration (ng/mL)

Standard

Ratio

CV%

80000

163.65

7.65%

20000

255.25

0.86%

5000

467.2

0.29%

1250

1581

6.71%

312.5

3420.5

4.53%

78.125

3980.1

3.49%

19.531

3704.5

0.02%

4.883

3785.5

3.90%

1.221

3673.5

1.56%

0.305

3940.5

8.06%

Blank

0

3965

3.92%

NC

NC

121.75

5.52%


Note: Recommended microplate (384-well plate, white, shallow well)

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 12388600503

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.0 ★★★★★
Based on 9 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
D
Verified Purchase
David
Pawtucket, US
★★★★★ 5
Great product
Color: Grey
Love this pillow...stays cool
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 6, 2026
J
Verified Purchase
Jason
Lexington, US
★★★★★ 3
Not 54" long, only 47.
Color: Grey
Not 54" long. It's the same length as my old 47" pillow, laid them out side by side and the same. Measures 47" with the tape measure. I got it because 47" wasn't long enough. It's soft and comfortable though, so I guess if you need a 47" it's fine. Not what I needed though.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 3, 2026
K
Verified Purchase
Kim W
Battle Creek, US
★★★★★ 5
It's much better then I expected.
Color: Grey
I love the length of this pillow and how fluffy it is. It really does stay cool to the touch.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 26, 2026
E
Verified Purchase
Eris
Pawtucket, US
★★★★★ 5
Just get it
Color: Grey
Super cold and not super firm, just really comfortable!! It’s worth your buck.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 3, 2026
M
Verified Purchase
Megan
Lexington, US
★★★★★ 5
Good purchase!!
Color: Blue(one-sided Cooling), Size: 20"x54"(Pack of 1)
It’s so comfortable!! Perfect cooling, soft to the touch, perfect length (I’m 5’4) it’s fluffy and firm. There is a little weight to it but still very nice!!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 30, 2026

recommand products