SKU: 91138548764

LC1K0901B7

Sale price$27.52 Regular price$30.58
Save 10%

Pay in installments of $7.64 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 4 - Aug 9

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

LC1K0901B7Main Range TeSys Product or component type Contactor Product name TeSys K Device short name LC1K Device application Control Contactor application Resistive load Motor control Complementary Utilisation category AC 3 AC 4 AC 1 Poles description 3P Power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: 690 V AC 50 60 Hz Signalling circuit: <= 690 V AC 50 60 Hz [Ie] rated operational current 20 A (at <50 C) at <= 440 V AC AC 1

Main
Range TeSys
Product or component type Contactor
Product name TeSys K
Device short name LC1K
Device application Control
Contactor application Resistive load
Motor control
Complementary
Utilisation category AC-3
AC-4
AC-1
Poles description 3P
Power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 24 V AC 50/60 Hz
Motor power kW 2.2 kW at 220...230 V AC 50/60 Hz AC-3
4 kW at 380...415 V AC 50/60 Hz AC-3
4 kW at 440 V AC 50/60 Hz AC-3
4 kW at 480 V AC 50/60 Hz AC-3
4 kW at 500...600 V AC 50/60 Hz AC-3
4 kW at 660...690 V AC 50/60 Hz AC-3
2.2 kW at 400 V AC 50/60 Hz AC-4
Auxiliary contact composition 1 NC
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity 110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit
85 A 50 °C - 5 s for power circuit
80 A 50 °C - 10 s for power circuit
60 A 50 °C - 30 s for power circuit
45 A 50 °C - 1 min for power circuit
40 A 50 °C - 3 min for power circuit
20 A 50 °C - >= 15 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in VA 30 VA (at 20 °C)
Hold-in power consumption in VA 4.5 VA (at 20 °C)
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate 3600 cyc/h
Auxiliary contacts type Type instantaneous 1 NC
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Mounting support Plate
Rail
Tightening torque 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Operating time 10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance 0.5 mm
Mechanical durability 10 Mcycles
Electrical durability 0.18 Mcycles 20 A AC-1 at Ue <= 440 V
1.3 Mcycles 9 A AC-3 at Ue <= 440 V
Mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Height 58 mm
Depth 57 mm
Net weight 0.18 kg
Environment
Standards BS 5424
IEC 60947
NF C 63-110
VDE 0660
Product certifications CSA
UL
IP degree of protection IP2x conforming to VDE 0106
Protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
Ambient air temperature for storage -50…80 °C
Operating altitude 2000 m without
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive Compliant
EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty
Warranty 18 months
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 91138548764

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.0 ★★★★★
Based on 14 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
L
Verified Purchase
Lyman D. Elliott
Natrona Heights, US
★★★★★ 5
One minor bug
Size: 10 Ft (Type B with Clamp), Color: Black
I received this today and mounted it to the table I have next to my recliner. I plugged it into a remote control outlet so I can turn everything off at once. I used two of the AC outlets for the power recliner. I then plugged a USB powered fan into one of the USB-A ports. I plugged the power cable from a set of speakers positioned next to the headrest of the recliner into the other USB-A port. I used one of the USB C outlets to charge my tablet. When I hit the switch on the remote control to turn off power to the strip before going to bed I discovered a bug. The only way I can describe it is a cross port power bleed. After killing power to the strip my speakers were still playing, not well as they had static. I discovered by trial and error that if I unplugged my tablet the problem stopped. Apparently if you have something with a battery plugged into one of the USB ports and have something plugged into the other USB ports it pulls power from the device with the battery to try and power the other devices plugged in. Other than this one problem it seems to be just what I was looking for.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 30, 2025
G
Verified Purchase
Glen T.
Draper, US
★★★★★ 5
Mounts to desktop
Size: 10 Ft (Type B with Clamp), Color: Black
Helps keep the desktop clutter down. Sometimes I need to charge flashlights, earphones, hearing aids, portable battery chargers and the like. I don’t want to plug these onto my computer so this unit fits that need. Sturdy desk mount so one hand plugging in and unplugging usually works fine.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 11, 2025
G
Verified Purchase
greasergrrl
Fort Morgan, US
★★★★★ 5
Works great
Size: 10 Ft (Type B with Clamp), Color: Black, Size: 10 Ft (Type B with Clamp), Color: Black
Small and does the trick. I’m glad my USB hub will stop falling off the table!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 28, 2025
A
Verified Purchase
Anne C.
Omaha, US
★★★★★ 4
Decent, gets warm though
Size: 10 Ft (Type B with Clamp), Color: Black
Compact with a nice long power cord. However, it does get warm, which makes me nervous, seeing as it is clamped to a wooden table...
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 23, 2026
N
Verified Purchase
Norart
Lowell, US
★★★★★ 1
Desktop charging station is defective.
Size: 10 Ft (Type B with Clamp), Color: Black
This item was purchased less than 6 months ago and today it suddenly stopped working. A defective unit. Will not buy again.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 19, 2025

recommand products