APC by Schneider Electric NetShelter SX 48U Duct Kit for Cisco Nexus® 7018

Sale price$1563.75 Regular price$1737.50
Save 10%

Pay in installments of $434.38 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Sep 8 - Sep 13

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

APC by Schneider Electric NetShelter SX 48U Duct Kit for Cisco Nexus® 7018The APC by Schneider Electric NetShelter SX 48U Duct Kit for Cisco Nexus 7018 is an expertly engineered air distribution solution designed to maximize cooling efficiency in power dense data center racks. Tailored for environments where high density equipment and low static pressure can challenge traditional cooling, this duct kit helps direct conditioned air precisely where its needed. By integrating seamlessly with APC NetShelter SX enclosures and

The APC by Schneider Electric NetShelter SX 48U Duct Kit for Cisco Nexus 7018 is an expertly engineered air distribution solution designed to maximize cooling efficiency in power-dense data center racks. Tailored for environments where high-density equipment and low static pressure can challenge traditional cooling, this duct kit helps direct conditioned air precisely where it’s needed. By integrating seamlessly with APC NetShelter SX enclosures and Cisco Nexus 7018 network switches, it delivers improved airflow management, reduced hotspots, and enhanced overall system reliability. If you’re looking to protect critical networking gear while maintaining optimal temperatures, this duct kit is a smart investment for scalable, energy-efficient data center operations.

  • Enhanced airflow management for power-dense racks: The duct design concentrates and channels cool air across dense Cisco Nexus 7018 deployments, helping to lower inlet temperatures and minimize hot spots in the rack enclosure.
  • Compatibility with NetShelter SX enclosures and Cisco Nexus 7018: Engineered to integrate with APC NetShelter SX systems and Cisco Nexus 7018 switches, ensuring a cohesive, plug-and-play airflow solution that preserves existing rack configurations.
  • Low-pressure, high-efficiency cooling: By optimizing air distribution, the kit supports lower fan speeds and reduced energy consumption while maintaining consistent cooling performance across all ports and blades.
  • Durable construction for data center environments: Built from rugged steel with a durable powder-coated finish, the duct kit withstands the rigors of daily data center operation and frequent access for maintenance.
  • Modular, scalable design for future growth: The kit’s modular components enable flexible configurations and straightforward expansion as your network grows and cooling requirements evolve.

Technical Details of APC NetShelter SX 48U Duct Kit for Cisco Nexus 7018

  • Compatibility: Designed for APC NetShelter SX enclosures and Cisco Nexus 7018 switches; works with standard 19-inch rack mounting rails.
  • Construction: Heavy-gauge steel with a durable powder-coated finish built to withstand demanding data center environments and frequent service access.
  • Air distribution features: Integrated duct plenums and configurable airflow paths to optimize cool air delivery to high-density equipment and adjacent devices.
  • Finish: Black powder-coated surface for a consistent aesthetic with APC NetShelter SX installations and compatible network gear.
  • Weight and dimensions: Weight and dimensions vary by configuration and rack size; exact figures are UPC/SKU-dependent and should be verified against product specifications for your setup.
  • Mounting and compatibility notes: Includes standard mounting hardware compatible with 19-inch rack systems; designed to fit the NetShelter SX line and support Cisco Nexus 7018 deployments.

How to Install APC NetShelter SX 48U Duct Kit for Cisco Nexus 7018

Installing the NetShelter SX 48U Duct Kit is a straightforward process designed to minimize downtime and help you achieve reliable airflow in a compact, power-dense rack environment. Follow these steps to ensure a secure, effective setup that delivers the intended cooling benefits for your Cisco Nexus 7018 and adjacent gear:

  • Preparation: Confirm compatibility with your NetShelter SX enclosure and Cisco Nexus 7018 model. Gather the included mounting hardware, tools, and any installers’ documentation. Power down non-essential equipment if required and follow your data center’s safety procedures.
  • Access and assessment: Open the enclosure doors and assess the current airflow layout. Identify the locations where the duct components will be installed to maximize intake air delivery to hot zones around the Nexus 7018 blades and adjacent devices.
  • Mounting the duct kit: Attach the duct plenums to the enclosure’s interior framework using the provided hardware. Ensure that all fasteners are snug but not over-tightened, and align the ducts with the intended airflow paths for optimal cold air delivery.
  • Sealing and cable management: Route cables neatly to avoid obstructing the airflow paths. Use any included gaskets or seals to minimize bypass air and maintain consistent pressure across the rack interior.
  • System configuration and testing: Restore power and gently power up the Cisco Nexus 7018 and related network gear. Monitor intake temperatures at critical points to confirm that the ducts are delivering the intended cooling and that no new hotspots have emerged.
  • Fine-tuning and maintenance: If temperatures indicate imbalances, adjust duct positions or add/remove plenums as needed. Periodically inspect the duct kit for dust buildup, loose fasteners, or wear, and perform routine cleaning to preserve airflow efficiency.

Frequently Asked Questions

  • What is the primary benefit of the NetShelter SX 48U Duct Kit for Cisco Nexus 7018? It optimizes airflow within power-dense racks, reducing hotspots and enabling more efficient cooling for high-density equipment, including Cisco Nexus 7018 switches, within NetShelter SX enclosures.
  • Is this duct kit compatible with other Cisco devices or only the Nexus 7018? The kit is designed for use with Cisco Nexus 7018 deployments in APC NetShelter SX enclosures; it may support other compatible devices when used in conjunction with the same enclosure and airflow path design, but consult product documentation for confirmation.
  • Do I need special tools to install the duct kit? Most installations rely on standard tools commonly used for rack hardware, such as hex wrenches or screwdrivers, along with the included mounting hardware. Always follow safety guidelines and your facility’s procedures.
  • Can the duct kit be reconfigured if my rack layout changes? Yes. The design is modular and scalable to accommodate evolving cooling needs and additional equipment; you can adjust plenums and pathways to suit new configurations.
  • How does this kit affect energy efficiency? By delivering cooler air more directly to high-heat zones, the kit supports optimized airflow, which can reduce fan speeds and lower overall energy consumption while maintaining stable operating temperatures.
  • Where can I find exact specifications for my UPC or SKU? Exact specifications such as weight and dimensions are SKU- and UPC-dependent. Check the product’s documentation or the official vendor catalog for precise figures associated with your specific UPC/SKU.
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 29698548653

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.6 ★★★★★
Based on 20 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
J
Verified Purchase
joseph g pope
Pawtucket, US
★★★★★ 1
Not everything included
It says it comes with program to reset the printer an all the information that came with the tanks takes you to sites that want you to buy the key to unlock. These were purchased with the idea everything you needed came with it.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 9, 2025
J
Verified Purchase
jody52770
Lexington, US
★★★★★ 5
Good must have product.
Good product, easy to install. A must have for Epson tank printer's. If you do the deep clean and over fill the head cleaning reservoir. Your your printer I'm set off a code that it is full and becomes trash cannot be reset.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 19, 2026
E
Verified Purchase
Erica R. Stinson
Houston, US
★★★★★ 5
Perfect to fix your Epson Ink Pad Counter Issue
Exactly what I needed! My Epson ET-4700 started displaying an 'E-11' error on the display so I learned I would have to replace the ink pad. The package came with 4 ink-pad receptacles, four baggies for discarding the old ones, plastic gloves and even a miniature screwdriver to get the backing off of the printer. The hardware part was super simple to remove the old and install the new. Hit a bit of a snag with the included software(which was a link to a website)which Windows Defender kept blocking no matter what I tried, but a quick email to support they answered right away. Sent me to a link for better software and I was able to successfully get my printer working again. A+++ transaction and service. Thanks again!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 20, 2025
K
Verified Purchase
2 Kids and a St. Bernard
Draper, US
★★★★★ 5
Will buy again
Worked extremely well
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 24, 2026
D
Verified Purchase
Debbie J.
Cuba, US
★★★★★ 5
Good product-May need to troubleshoot
I am giving this product five stars even though I had issues resetting my printer because it was not product fault. The maintenance box was easy to install. Based on other reviews, I was prepared for the wic reset site that looked suspicious. I will say it is legit. I purchased a reset key which I later found out that I did not need. Read further and I will explain. After I downloaded the WIC software, I spent over 2 hours troubleshooting yrying to reset my printer. I am writing this hoping that it might help others. In the end, the problem was my Wi-Fi was not recognizing the printer. When I was trying to reset it. I ended up connecting my printer via USB cable and I was immediately able to reset my printer and start printing again. I am going to list the troubleshooting steps I took, but you might want to try that first. In addition, before purchasing a reset key, they do offer a trial key. If you have never used a trial on that printer. I suggest doing this first because in the end I used the trial rather than the key that I had purchased. Here are a few additional troubleshooting steps you could try: 1. Ensure Correct Reset Key: Double-check that the reset key you purchased is for the correct model of your printer. If it's specific to another model or region, it may not work correctly. 2. Reinstall WIC Software: Uninstall and reinstall the WIC software to make sure it's functioning properly. Sometimes a corrupted installation can cause errors. 3. Run the Software as Administrator: Make sure you are running the WIC software as an administrator. Right-click on the WIC Reset tool icon and choose "Run as Administrator." 4. Disable Firewall/Antivirus Temporarily: Your firewall or antivirus software may be interfering with the connection. Temporarily disable them and try again to see if that helps. Make sure to turn it back on when finished. 5. Try a Different USB Port: If you are connecting via USB, try switching to another port. Alternatively, if you're using Wi-Fi, you might want to try a USB connection to see if that helps the software communicate with the printer. This is what worked for me. 6. Use a Different Computer: If possible, try using the reset software and key on a different computer. Sometimes system-specific issues can interfere with communication between the software and the printer. 7. Check for Firmware Updates: Ensure that your printer's firmware is up to date. If it's outdated, it might cause incompatibility with the reset tool. Be cautious, as some updates can prevent third-party reset tools from working. If none of the above works, it might be worth contacting the vendor of the reset key. They may have specific guidance or offer a replacement key if the one you purchased is faulty. Last resort would probably be to call Epson.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 20, 2024

recommand products