SKU: 24457930245

Mouse ADH ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Pay in installments of $46.03 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Sep 11 - Sep 16

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Mouse ADH ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: 1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)
2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL
3. 37℃ constant temperature box
4. Distilled water or deionized water

Sample processing and requirements:
1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.
2. Plasma: Collect specimens using EDTA or heparin as an anticoagulant and centrifuge at 1000×g for 15 minutes at 2-8°C within 30 minutes of collection. Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing.
3. Cell culture supernatant: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing.

Pre-Test Preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.
2. Prepare a gradient standard working solution: Add 1 mL of universal diluent to the lyophilized standard. Let stand for 15 minutes to completely dissolve, then gently mix (concentration 20 ng/mL). Then dilute to the following concentrations: 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 20 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 10 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details.
3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately.
4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately.
5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C.
2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.)
3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes.
4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used).
5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes.
6. Washing: Discard the liquid and wash the plate five times as in step 4.
7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.
8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.
2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with an alcohol dehydrogenase (ADH) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of alcohol dehydrogenase (ADH) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Mouse
Synonym Mouse Alcohol dehydrogenase(ADH) ELISA kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Alcohol dehydrogenase (ADH), abundant in animal liver, plant, and microbial cells, is a zinc-containing metalloenzyme with broad substrate specificity. It is an 80 kDa dimer comprising a group of isoenzymes that are capable of converting ethanol to acetaldehyde. In mammals, this is a redox reaction involving the coenzyme nicotinamide adenine dinucleotide (NAD+). ADH catalyzes the oxidation of primary and secondary alcohols to aldehydes and ketones and can also influence the reverse reaction. In mammals, ADH and aldehyde dehydrogenase (ALDH) form the ADH system, participating in ethanol metabolism and serving as crucial metabolic enzymes in animals. As a key enzyme in the metabolism of the primary short-chain alcohol, ADH plays a vital role in numerous physiological processes.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 0.312-20 ng/mL
Applications Serum, plasma, cell culture supernatant
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 24457930245

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.1 ★★★★★
Based on 27 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
S
SKS
Chelsea, US
★★★★★ 5
Worked in RDX 2nd gen
It fit perfect in RDX 2nd gen. The filter built quality looks pretty much like OEM or better. I do not see any performance issue. Price was reasonable. Its a good buy.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 13, 2024
Y
Verified Purchase
Yianni Tripodis
Charlottesville, US
★★★★★ 5
Price/Quality
Packaged very well, perfect fit and the quality looks great. Well worth the price.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 11, 2026
R
Verified Purchase
Roscoe and Tori
Cuba, US
★★★★★ 5
DIY!!
Bought this cabin air filter for my 2015 Honda CR-V and it fit perfectly. Installation was super easy and only took a few minutes. I immediately noticed the air coming through the vents smelled cleaner. No need to have it replaced for you. Definitely worth it if you want an affordable replacement that gets the job done.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 19, 2026
B
Verified Purchase
Ben W.
Battle Creek, US
★★★★★ 5
Perfect replacement
Perfect replacement for our 2016 Acura RDX. Easy to install.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 3, 2026
H
Verified Purchase
H.Tran
Bozeman, US
★★★★★ 5
Impressive Air Quality Upgrade
I recently upgraded my 2019 Honda Civic with the A-Premium Cabin Air Filter with Activated Carbon, and I couldn't be more thrilled with the results. This cabin air filter offers exceptional value for money, proving that you don't have to break the bank for improved air quality inside your car. Installing the A-Premium Cabin Air Filter was a breeze. It fit perfectly into my Honda Civic's existing filter slot, and the installation process was straightforward, even for someone with limited automotive knowledge. The filter's precise dimensions and design made it a seamless replacement, saving me time and effort. The included instructions were clear and concise, further simplifying the installation process. The activated carbon feature of this cabin air filter is truly remarkable. It works wonders in improving the air quality inside the car's cabin by effectively trapping and neutralizing odors, pollutants, and allergens. I immediately noticed a significant difference after installing the A-Premium filter. The cabin air felt fresher, and I could breathe easier knowing that the filter was efficiently removing harmful particles and unpleasant smells. Considering the affordability of this product and the tangible benefits it provides, the A-Premium Cabin Air Filter with Activated Carbon is an excellent investment. It delivers on its promise to enhance the air quality inside your vehicle, making your driving experience more comfortable and enjoyable. If you're seeking an affordable yet effective cabin air filter upgrade for your 2019 Honda Civic, I highly recommend the A-Premium Cabin Air Filter with Activated Carbon. Its exceptional value for money, ease of installation, and remarkable impact on air quality make it a standout choice that won't disappoint. Upgrade your driving environment today and experience the difference for yourself.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 25, 2023

recommand products