LC1D12G7Main Range TeSys Product name TeSys D Product or component type Contactor Device short name LC1D Contactor application Motor control Resistive load Utilisation category AC 3 AC 4 AC 1 Poles description 3P Power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: <= 690 V AC 25 400 Hz Power circuit: <= 300 V DC [Ie] rated operational current 25 A (at <60 C) at <= 440 V AC AC 1 for power circuit 12 A (at <60 C) at <= 440 V AC AC
Main
| Range | TeSys |
| Product name | TeSys D |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-3 AC-4 AC-1 |
| Poles description | 3P |
| Power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| Motor power kW | 3 kW at 220...230 V AC 50/60 Hz (AC-3) 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) 5.5 kW at 415...440 V AC 50/60 Hz (AC-3) 7.5 kW at 500 V AC 50/60 Hz (AC-3) 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) 3.7 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power HP (UL / CSA) | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 120 V AC 50/60 Hz |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 25 A (at 60 °C) for power circuit 10 A (at 60 °C) for signalling circuit |
| Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 105 A 40 °C - 10 s for power circuit 210 A 40 °C - 1 s for power circuit 30 A 40 °C - 10 min for power circuit 61 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 40 A gG at <= 690 V coordination type 1 for power circuit 25 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified |
| Electrical durability | 2 Mcycles 12 A AC-3 at Ue <= 440 V 0.8 Mcycles 25 A AC-1 at Ue <= 440 V |
| Power dissipation per pole | 0.36 W AC-3 1.56 W AC-1 |
| Safety cover | With |
| Mounting support | Rail Plate |
| Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
| Product certifications | DNV GOST GL CSA BV LROS (Lloyds register of shipping) UL RINA CCC |
| Connections - terminals | Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end |
| Tightening torque | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat √ò 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat √ò 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 |
| Operating time | 12...22 ms closing 4...19 ms opening |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Maximum operating rate | 3600 cyc/h 60 °C |
Complementary
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C) Operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C) Operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C) |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C) 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C) 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Auxiliary contacts type | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Insulation resistance | > 10 MOhm for signalling circuit |
Environment
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Pollution degree | 3 |
| Ambient air temperature for operation | -5…60 °C |
| Ambient air temperature for storage | -60…80 °C |
| Permissible ambient air temperature around the device | -40…70 °C at Uc |
| Operating altitude | 3000 m without |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 86 mm |
| Net weight | 0.325 kg |
Offer Sustainability
| Sustainable offer status | Green Premium product |
| REACh Regulation | REACh Declaration |
| REACh free of SVHC | Yes |
| EU RoHS Directive | Under investigation |
| Toxic heavy metal free | Yes |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.1 ★★★★★
Based on 5 reviews
Sort
Product Reviews
★★★★★ 5
Great references book.
Format: Hardcover
Excellent book for medical reference and refresh of knowledge.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 28, 2026
★★★★★ 5
A Wonderful Update To A Great Old Reference Book!
Format: Hardcover
It's the Merck Manual! If you know medicine but are aware you don't know EVERYTHING about EVERYTHING! (Few if any do!) This is a wonderful reference. If you have no medical knowledge and think this will make you know what doctors know. Don't waste your money. You have to have a basic understanding for this to be helpful. This is a wonderful update to an old favorite.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on July 16, 2025
★★★★★ 5
The most current and inclusive medical reference available mid-2018.
Format: Hardcover, Format: Hardcover
Here’s the review I wrote for the 19th edition on 2011: I've been getting and using the Merck Manual for over 30 years to answer questions about disease for family and friends (pediatrics through geriatrics) as well as preparing to ask germane questions of physicians responsible for care of family and friends. It is comprehensive in its coverage of the etiology, diagnosis, treatment and prognosis of diseases of the human body and contains the latest research results on the treatment options. It's really not that difficult for the layman to understand the medical terminology and the result is factual understanding of the major aspects of disease which you will NOT get from the standard home health care books from Johns Hopkins, Harvard, Mayo Clinic, the AMA or even the Merck Home Health handbook. And, unlike the Merck Manual, these books directed to the laity do not contain the diagnostic information upon which physicians decide precisely what disease they are presented with. Yes, there will be much superfluous information which you may never use, but, when you want and need the information about a specific disease, here's where you should start your education.
The same holds true for the updated 2018 20th edition. I neglected to mention that this manual also contains a plethora of ancillary information including thorough sections on pediatrics, geriatrics, injuries, bites and stings, patient care, alternative medicine, dietary supplements, rehabilitation, normal test values and even legal issues such as advance directives. Yup, it’s pricey, but it’s always proved to be valuable to me.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 15, 2018
★★★★★ 5
Great reference book
Format: Hardcover
If you only have one medical resource book in your house, I recommend this one. Very thorough book.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 3, 2026
★★★★★ 5
Good to Have
Format: Hardcover
This is a comprehensive manual. I bought it because of the difference of opinions of different doctors and vets that we received when our cat was sick. We spent over $6,000+ and found out he only had 1 of the 7 symptoms of his diagnosis and the hospital could not find the reason for his weight loss. Many years ago a human Merck Manual helped us discover that the specialist was using one. After coming out of the hospital and during a followup visit, I asked what is the next step to take. I advised him we bought a Merck Manual and can read it just as well as him and was not happy. He sent us to an Electrophysiologist, a speciality we never knew existed.
Kitty gained weight again, just needed to peak his appetite with Instinct Rabbit and Duck dry cat food. Apparently, his smell was off and Instinct coats their kibble with the flavor you are buying. It wasn’t easy finding the right one because he is food specific and it must be kibble. We donated all the ones recommended and others we thought he would the rescues. When we first adopted him as a kitten, he was sneezing mucous tinted with blood and vet said he would grow out of it. He did but ….
Highly recommend double checking and / or getting a 2nd opinion, human or otherwise.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 26, 2024